Automatically detects improper test setups and abnormal conditions. Certified for explosion-hazardous areas (ATEX, IECEx, FM). IP64-compliant for wet environments. Compatible with all current cleaning agents and VHP
Features adjustable X, Y, and Z axes for specimen positioning. Includes ASTM D 5025-compliant burner with 0°, 20°, or 45° angle adjustment. Contains precise gas control system with flow meter and pressure regulator. Operates with microcomputer control and high automation level. Has 0.9 square meter internal volume with internal lighting
Replaces multiple individual testing devices for substation asset commissioning. Operates via integrated front panel or Primary Test Manager software. Provides up to 800 A or 2 kV testing with up to 5 kVA power. Weighs only 29 kg for easy on-site testing. Uses variable frequency to suppress mains interference
Universal solution for testing all protection relay generations. Six current sources up to 64 A / 860 VA per channel. High current amplitudes for 5 A relay testing. Integrated network for IEC 61850 IED testing
Device must be grounded when powered by 100/240V AC. Air quality must be clean and dry with minimum 0.6 MPa pressure. Electrical connections should be shorter than 2 meters
Front panel integration device measuring voltage quality according to EN61000-4-30. Dimensions 144x144mm with 320x240 color display and 6 buttons. Operates in TN and TT networks with 2-4 conductor systems. Temperature measurement input and 2 digital outputs/inputs