• Buradasın

    Unmanned Machinery Space System (UMS)

    maritimepage.com/unmanned-machinery-spaces-or-ums-on-ships/

    Yapay zekadan makale özeti

    System Overview
    • UMS sends engine room malfunctions to duty engineer's cabin through extension alarms
    • System activates between 1700H to 0800H
    • Duty engineer must check engine room before UMS activation
    Key Requirements
    • Fire detection and extinguishing systems must be installed
    • Emergency generators should start within minute of blackout
    • Navigation bridge must control engine speed and thrust
    • Bilge wells should have high alarm levels and automatic pump control
    Engine Room Monitoring
    • Dead man alarm system must be activated before entering engine room
    • Freshwater tanks and generators should be monitored regularly
    • Air conditioners and refrigeration units need proper maintenance
    • Fire and smoke alarms must be operational
    Safety Features
    • Extension alarm systems must be audible in all cabins
    • Bilge pumps should be in auto start/stop mode
    • Emergency stop system should be available
    • Fire zones must be isolated